Installing The DXOPT–COM Communications Card
In The DXP Plus Digital Communications System
1.0 Understanding The Communications Card
The communications card provides serial data ports for interfacing such items as open architecture interface
applications, PC attendant positions, and the SMDA data printer.
NOTE: The serial data ports located on the CPU board are dedicated to PC-based programming and the remote
maintenance modem.
You can install communications cards on the services board, the expansion cabinet interface boards, and the main
cabinet’s auxiliary board. Each of these boards will accept two communications cards in its lower two slots.
The DXP Plus supports a maximum of 18 serial data ports. Two of these ports are the dedicated ports provided by
the CPU board while communications cards provide the remaining 16 undedicated ports. The system designates
serial data ports 3–18 to specific locations as detailed in the following chart.
Serial Data Port Designation*
DXOPT–COM Location
Serial data ports 3–10
Lower two slots on the services board
Serial data ports 11–18
Lower two slots on one of the three following locations:
— the upper expansion cabinet interface board
— the lower expansion cabinet interface board
— the auxiliary board installed in the main cabinet.
You must take programming action to match the data
port number with the installation location that you
choose for the communications card.
* The full compliment of 16 undedicated serial data ports requires four installed communications cards.
1.1
Communications Card Connections
The interface connector between the external device and the communications card is a standard modular jack, and
each serial data communications port supports various baud rates, data bits, stop bits, parity, and flow control.
You can program these various options using data base programming.
R
This manual has been developed by Comdial Corporation (the “Company”) and is intended for the use of its customers and service personnel. The information in this manual is subject to change
without notice. While every effort has been made to eliminate errors, the Company disclaims liability for any difficulties arising from the interpretation of the information contained herein.
The information contained herein does not purport to cover all details or variations in equipment or to provide for every possible contingency to be met in connection with installation, operation, or
maintenance. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, contact Comdial, Inside Sales Department,
Charlottesville, Virginia 22906.
Printed in U.S.A.
IMI89-190.01
7/95
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...