3.0 Configuring The DXPT1 Board
Before you install the DXPT1 board, determine if you must meet special system requirements such as fractional
service (8 or 16 channel operation). If you do have special system requirements, use the dual in-line pin (DIP)
switches provided on the board to re-configure the DXPT1 board.
The DXPT1 board contains 28 DIP switches (three 8-position modules and one 4-position module). Rectangular
cutouts in the front-edge panel provide access to these switches.
The eight DIP switches nearest the bottom of the panel are accompanied by eight green LED indicators.
NOTE: These eight switches and their associated indicators are for factory diagnostic purposes only.
The remaining 20 DIP switches labeled SW1, SW2. and LIU are for configuring the DXPT1 board to meet
specific operating requirements. See Figure 2. The default setting for all of these switches is 0 (on the left as you
face the front edge of the board). This is the standard superframe (SF) configuration for most customer
applications. However, special customer needs may require that you reset one or more of these switches using the
procedure given below.
1. Obtain a static discharge wrist strap (supplied with the main DXP cabinet) and attach it to one of your wrists.
Make sure to adjust the strap for a snug fit against your skin; do not apply the strap over any of your clothing.
2. Connect one end of the wrist strap-cord to the wrist strap and the other end to earth ground.
NOTE: With the DXP cabinet in the installed position, the ground lug on the right side of the cabinet is normally
a good grounding point since this lug should have a heavy ground wire connected between it and a good
earth ground.
3. Remove the DXPT1 board from its static protection bag and set it on a static-safe work area.
4. Using a ball-point pen or similar object, move the DIP switches from left (0 position) to right (1 position) as
needed. All DIP switches are facing left for typical applications. See Tables 1, 2, and 3 for descriptions of the
DIP switches.
IMI89–193
Installing The DXPT1 Line Board
4 – Installing The DXPT1 Line Board
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...