2.0 Installing The ExecuMail System
At Analog Station Ports
When you interface the ExecuMail system to the DXP Plus system through the analog station ports on its analog
station board, you must place the Comdial Voice Mail Interface device (VMI–X) between the ExecuMail ports
and the system’s station ports. The VMI–X includes two circuits; therefore, you will need one device for every
two ExecuMail ports that you plan to connect. This means that for a four-port ExecuMail system, you will
need two VMI–X devices.
The VMI–X device has its own power supply that connects to the AC power line.
2.1
Installing The VMI–X
Be sure the mounting location is secure and dry, has adequate ventilation, and is a large enough area to allow easy
placement of the VMI-X. The temperature range of the location must be within 32 - 90° F (0 - 40° C).
Be sure that you have the following tools and hardware available for mounting the VMI–X:
•
Fasteners, such as 1/4-inch wood screws, of a sufficient length to securely bite into mounting backboard
•
Cross Recessed screwdriver (phillips-head type)
•
Flat-blade Screwdriver
•
Electric Drill if prepared holes are needed
•
Connecting tool - for fastening wires to a type-66 connector block.
•
Crimping tool - for 623-type modular plugs.
1. Unpack, and carefully inspect the VMI–X for shipping damage. Notify the shipper immediately of any
damages found. Verify that the package contains all parts and accessories needed for proper installation and
operation.
2. Locate the VMI–X device within 25 feet of both the common equipment cabinet and the ExecuMail system.
3. If a backboard is required at the mounting location, attach it securely to provide a stable mounting surface.
4. Use the base of the VMI–X cabinet as a template or measure for mounting hole locations per the dimensions
shown in the outline dimensions drawing located on the next page.
5. Drill holes of a proper size to accommodate the hardware being used into the mounting surface. If necessary,
prepare these holes with inserts, anchors or other attachment devices as dictated by the type of mounting
surface.
6. Insert the screws into the mounting surface and tighten them to within approximately 1/8-inch of the surface.
7. Hang the VMI–X cabinet on the screws using the mounting holes located on the rear of the cabinet. Note that
these holes are elongated with an enlargement at one end. This feature allows the cabinet to snap down on the
screws to secure the mounting when the cabinet is hung on them.
2.2
Setting The Configuration Switches
Set the configuration switches that are located on the left side of the VMI–X housing to match the DXP Plus and
ExecuMail systems. Refer to the illustration shown on the next page and set the switches as detailed on this table.
Switch
Setting
A
Closed
B
Closed
C
Open
D
Open
IMI89–206
Installing And Programming For ExecuMail
2 – Installing And Programming For ExecuMail
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...