2.4
Making The PC Attendant Position Connections
1. Connect the supplied modular-to-EIA adapter to the
COM1
serial data connector on the PC attendant position
personal computer.
2. Connect the supplied 6–conductor (with ferrite collar) line cord between the modular-to-EIA adapter and the
modular jack that is wired to the DXP Plus serial data port. Keep the ferrite collar near the PC attendant
position.
3. Connect the supplied 4–conductor line cord between the
LINE
jack on the proprietary interface board and the
modular jack that is wired to the DXP Plus line board.
4. Connect the handset coil-cord to the
HANDSET
jack on the proprietary interface board. Note that the
interface also provides a
HEADSET
jack if the user requires headset operation.
5. Disconnect the telephone that the PC attendant position replaces. Record its physical board slot location and
its logical station number for use when programming the system to accept the PC attendant position.
6
5
4
3
2
1
PCATND5
9
8
7
6
5
4
3
2
1
Modular Jack
Pin 1 = No Connection
Pin 2 = (SG) Signal Ground
Pin 3 = (TD) Transmit Data
Pin 4 = (RD) Receive Data
Pin 5 = (CTS) Clear to Send
Pin 6 = (RTS) Request to Send
DB9 Connector
Pin 1 = No Connection
Pin 2 = (RD) Receive Data
Pin 3 = (TD) Transmit Data
Pin 4 = No Connection
Pin 5 = (SG) Signal Ground
Pin 6 = No Connection
Pin 7 = (RTS) Request to Send
Pin 8 = (CTS) Clear to Send
Pin 9 = No Connection
Detailing The Modular–To–EIA adapter
IMI89–195
Installing And Programming The PC Attendant Position
8 – Installing The PC Attendant Position
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...