Examining The Enable QuickQ Status Utility
The enable QuickQ status allows you to enable the
QuickQ after you have programmed the voice port
extensions and without resetting the computer. After
you have enabled QuickQ, the enable QuickQ option
will be the QuickQ status feature. This feature
indicates QuickQ‘s current operating status.
The enable QuickQ status option can provide
information on the hardware status as seen by QuickQ
upon initialization and after you display the QuickQ
status window. The messages that will appear are
shown on the following list.
All Components acquired This indicate that the lines
and the Voice Ports are
functioning.
Line not initialized
This indicates a problem
with a line that was
programmed as an ACD
line. Check the line going
into the QuickQ DVA.
Check programming of lines
in ACD.
Link established
between PC and DVA
This indicates that there is
proper RS-232 serial data
communication between the
PC and the DVA but there
is a problem with one of the
other initialization
parameters.
Lost link between
PC and DVA
This indicates a problem
with the RS-232 serial data
communication link. Check
all serial communication
wiring plus, be sure the
DVA is powered on.
Voice Ports not initializedThis indicates a problem
with a voice port card that
you have programmed as a
message channel. Check
the wiring between the
DVA and the DXP station
port. Also check the QuickQ
message channel and
extension length
programming for the voice
port extension.
All voice ports initialized This indicates all voice port
cards programmed in
QuickQ are functioning
properly but there is a
problem with one of the
other initialization
parameters.
QuickQ initialized
This indicates the ACD
software is initialized.
OAI Key Code = xxx
This indicates the OAI key
code.
The QuickQ status window provides information on
the communication status of QuickQ andthe feature
codes. The messages that show are listed below.
Lost communication
with announcer
This indicates a problem
with the RS-232 serial
communication link.
Check all serial
communication wiring and
be sure the DVA is powered
on.
Normal communication
with announcer
This indicates correct
RS-232 serial
communication between the
PC and the DVA.
OAI Key Code = xxx
This indicates the OAI key
code.
IMI66-109, Section 7
Testing And Troubleshooting
Testing And Troubleshooting 7 – 3
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...