Relays
(External Paging Equipment
Description:
If your installer connects customer-supplied external paging equipment to the system’s external
paging port and that equipment requires external control, use this programming procedure to
assign a relay to control the paging equipment. Also refer to Section 6.10.9.
Programming:
1. Press CONTROL T for main menu.
2 . From main menu, select system and press ENTER.
3 . From systems menu, select paging zones and press ENTER.
4 . From paging zones menu, select zone programming and press ENTER.
5 . Enter zone number (l-8) and press ENTER.
6 . From zone programming menu, type item number for relays and press ENTER.
7 . Type relay number
= none) and press ENTER.
8 . When finished, press ESCAPE twice.
9 . Type y to accept changes, n to reject them, or r to resume editing and press ENTER.
10. Repeat steps 4-9 for each zone or press ESCAPE to end.
Relays
(Line Answer From Any Station)
Description:
Assign one or more of the four relays located on the central processor board to track the ring
signal of any or all line ports. You can arrange for a relay to track the ringing of the direct,
delayed, day 1, day 2, or night ringing modes. Typically, installers wire these
relays to control
loud bells or other external ringers.
Users, upon hearing the external ringers, can dial feature
codes to answer the call that is ringing on the associated lines.
Programming:
1. Press CONTROL T to return to main menu.
2. From main menu, select system and press ENTER.
3. From the system menu, select paging zones and press ENTER.
4. From the paging zones menu, select relays and press ENTER.
5. From the relays menu, select relay l-4 and press ENTER.
6. From the relay n menu, type item number for ring type and press ENTER.
7. Press CONTROL E for edit menu.
8. From edit menu, type a to add or r to remove and press ENTER.
9. Type line port numbers l-240 (type as n,nn,nnn or n-nnn to add or remove
and press ENTER.
10. Press ESCAPE and repeat steps 6-9 for other ring types.
11. When finished press ESCAPE twice.
12. Type y to accept changes, n to reject them, or r to resume editing and press ENTER.
13. Repeat steps 5-12 for other relays.
14.
Press ESCAPE to end.
Operation:
dial 6 5 = relay 1, dial 66 relay 2, dial 67 relay 3, dial 68
relay 4 ,
dial 6 9 = relays 1 through 4 (when programmed with ringing)
Sys tern Features Programming
37
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...