Mounting The Equipment
Typically, you should mount the QuickQ DVA cabinet
near the DXP installation; however, you can locate the
DVA cabinet at a maximum distance of 1000 feet
from the DXP if you use #24 twisted-pair wiring. You
must locate the Central Call Processor (personal
computer) within 500 feet of the DXP and DVA
cabinets. If you exceed this distance, you must install
limited distance modems at either end of your cable
run.
1. Unpack and carefully inspect all equipment for
shipping damage. Notify the shipper immediately
of any damages found. Verify that the packages
contain all parts and accessories needed for proper
installation and operation.
2. If a backboard is required at the mounting location,
attach it securely to provide a stable mounting
surface for the equipment.
3. Hold the DVA cabinet against the mounting
surface, level it, and mark the location of the two
upper mounting holes.
4. Drill holes in the mounting surface of a proper size
to accommodate the hardware being used.
If necessary, prepare these holes with inserts,
anchors or other attachment devices as dictated by
the type of mounting surface.
5. Insert the two top screws into the mounting surface
and tighten them to within approximately 3/16-inch
of the surface.
6. Hang the cabinet on the top screws using the
mounting holes located on the rear of the cabinet.
Note that these holes are elongated with an
enlargement at one end. This feature allows the
cabinet to snap down on the screws to secure the
mounting when the cabinet is hung on them.
7. Install the remaining two mounting screws through
the lower mounting holes in the DVA cabinet and
into the mounting surface.
8. Tighten all four screws into place.
9. Mount the QuickQ-supplied and wired 66-type
connector block near the DVA cabinet (typically
within 5 feet or less).
Installing The QuickQ System
IMI66–109, Section Two
Installing The QuickQ System 2 – 3
Содержание DXP Plus Series
Страница 1: ...Digital Communications System R ...
Страница 363: ...Automatic Call Distributor Technical Manual R QuickQ DXP ...
Страница 424: ...Automatic Call Distributor System Manager s Guide R QuickQ DXP ...
Страница 500: ...Wrap up Time 1 6 Wrapping Up A Call 4 3 Z Zoom Box A 2 GCA70 271 Index I 3 ...
Страница 628: ...Interconnecting The VMI X Installing And Programming For ExecuMail IMI89 206 Installing And Programming For ExecuMail 5 ...
Страница 677: ...Connecting The Equipment Installing And Programming The OPX X IMI89 209 Installing The OPX X 7 ...
Страница 728: ...DP I I I I and FX Series Digital Communications Systems Understanding The Visual Man Machine Interface COMDlA ...
Страница 1112: ...9 08 8 90 1 13 4 78 3 94 UNIS029 TAB003 PLS page 6 GCA40 130 DXP Plus General Description 11B Telephone Features ...