Detailing Typical Data Device Connections
PLUS044
1
2
3
4
5
6
1
2
3
4
5
6
Serial Modem Port
Maintenance Port
Modular Jacks
Pin 1 = Request To Send
Pin 2 = Clear To Send
Pin 3 = Receive Data
Pin 4 = Transmit Data
Pin 5 = Signal Ground
Pin 6 = Frame Ground
(Front View of Jacks)
NOTES:
1.
2. Some data devices require
CTS signal for proper
operation. Route to device
as needed.
Maximum distance between
each ofthe two dedicated
serial data ports and its
external data equipment
is 25 feet.
Installing The DXP Plus Main Cabinet