Operating Manual 1302.6163.12 - 03
6.237
R&S ESU
Remote Control – Description of Commands
SYSTem Subsystem
Mode:
R, A
SYSTem:COMMunicate:RDEVice:GENerator<1|2>:TYPE
<name>
This command selects the type of external generator 1 or 2. For a list of the available generator types
including the associated interface, see chapter
“External Generator Control – Option R&S FSP-B10”
,
section
“List of Generator Types Supported by the R&S ESU” on page 4.347
Example:
"SYST:COMM:RDEV:GEN2:TYPE 'SME02'"
'Selects SME02 as generator 2.
Characteristics:
*RST value: NONE
SCPI: device-specific
Mode:
R, A
SYSTem:COMMunicate:SERial:CONTrol:DTR
IBFull | OFF
SYSTem:COMMunicate:SERial:CONTrol:RTS
IBFull | OFF
These commands switch the hardware handshake procedure for the serial interface off (OFF) or on
(IBFull).
The two commands are equivalent.
Example:
"SYST:COMM:SER:CONT:DTR OFF"
"SYST:COMM:SER:CONT:RTS IBF"
Characteristics:
*RST value: -- (no influence on this parameter, factory default OFF)
SCPI: conform
Mode:
R, A
SYSTem:COMMunicate:SERial[:RECeive]:BAUD
110 | 300 | 600 | 1200 | 2400 | 9600 | 19200 | 38400
| 57600 | 115200 | 128000
This command sets the transmission speed for the serial interface (COM).
Example:
"SYST:COMM:SER:BAUD 2400"
Characteristics:
*RST value: -- (no influence on this parameter, factory default 9600)
SCPI: conform
Mode:
R, A
SYSTem:COMMunicate:SERial[:RECeive]:BITS
7 | 8
This command defines the number of data bits per data word for the serial interface (COM).
Example:
"SYST:COMM:SER:BITS 7"
Characteristics:
*RST value: -- (no influence on this parameter, factory default 8)
SCPI: conform
Mode:
R, A
Generators with TTL interface can also be operated via GPIB alone.
With NONE selected, the corresponding generator 1 or 2 is deactivated.
The command is only available with option Ext. Generator Control, R&S FSP-B10.
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...