Operating Manual 1302.6163.12 - 03
4.195
R&S ESU
Instrument Functions
Analyzer Mode
Measurement with user-specific channel configuration:
Measurement of the adjacent-channel power ratio (ACPR) of an IS95 CDMA signal
at 800 MHz, level 0 dBm. Similar to example 1, the setting can be simplified by using
CP/ACP STANDARD
.
[
PRESET
]
Set the R&S ESU to the default setting.
[
FREQ:
CENTER
: 800
MHz
]
Set the center frequency to 800 MHz.
[
AMPT
: 0
dBm
]
Set the reference level to 0 dBm.
[
MEAS
]
Call the menu for the measurement functions.
[
CHAN PWR / ACP
]
Select the channel and adjacent-channel power measure-
ment function. The measurement is carried out with the
default settings or a previously defined setting. The sub-
menu for setting the desired new configuration is opened.
[
CP/ACP CONFIG
]
Call the submenu for defining the channel configuration.
[
NO. OF ADJ CHAN
:
2
ENTER
]
Select two adjacent channels for the measurement, i.e.
the adjacent channel and the alternate channel are mea-
sured.
[
CHANNEL
BANDWIDTH
: 1.23
MHz
:
U
d
: 30
kHz
]
Set the channel bandwidth to 1.23 MHz in accordance
with IS 95. Set the adjacent-channel bandwidth to 30 kHz.
Upon entry of 30 kHz for the adjacent channel the alter-
nate channels are also set to 30 kHz.
[
CHAN SPACING
: 1.25
MHz
:
U
d
885
kHz:
U
d
: -
1.98
MHz
]
U
d
: 2.97
MHz
]
Open the list for entering the channel spacings.
Upon entry of 885 kHz for the adjacent channel the chan-
nels ALT1 and ALT2 are set to 1770 kHz and 2655 kHz.
Upon entry of 1.98 MHz for the alternate channel 1 the
alternate channel 2 is set to 2.97 MHz.
[
ADJUST SETTINGS
]
Automatically set the optimum span (= 5 MHz), resolution
bandwidth (RBW = 30 kHz), video bandwidth (VBW = 300
kHz) and detector (RMS) for the measurement. The abso-
lute channel power and the relative power of the adjacent
channels and alternate channels are displayed on the
screen.
Go to the main menu for channel power measurement.
[
ADJUST REF LVL
]
Set the reference level equal to the channel power mea-
sured.
TX/ACP CHANNEL BW
CHAN BANDWIDTH
ADJ 30 kHz
ALT1 30 kHz
ALT2 30 kHz
TX 1.23 MHz
TX/ACP CHAN SPACING
CHAN SPACING
ADJ 885 kHz
ALT1 1.98 MHz
ALT2 2.97 MHz
TX 1.25 MHz
PREV
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...