
Operating Manual 1302.6163.12 - 03
6.293
R&S ESU
Remote Control – Description of Commands
Differences in GPIB Behavior between the FSP and the FSE Families of Instruments
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ACHannel:ABSolute
-200 to 200 DBM,
-200 to 200 DBM
new function for
R&S ESU
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ACHannel:ABSolute:STATe
ON | OFF
new function for
R&S ESU
R&S
ESU
FSE
CALCulate<1|2>:LIMit<1...8>:ACPower:
ACHannel:RESult?
FSE
CALCulate<1|2>:LIMit<1...8>:ACPower:
ACHannel:STATe
ON | OFF
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ACHannel[:RELative]:
STATe of R&S ESU
not available for FSET
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ACHannel[:RELative]
0 to 100 DB,
0 to 100 DB
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ACHannel of FSE
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ACHannel[:RELative]:STATe
ON | OFF
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ACHannel:STATe of FSE
FSE
CALCulate<1|2>:LIMit<1...8>:ACPower:
ALTernate<1|2>
0 to 100 DB,
0 to 100 DB
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ALTernate<1|2>
[:RELative] of R&S ESU
not available for FSET
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ALTernate<1|2>:ABSolute
-200 to 200 DBM,
-200 to 200 DBM
new function for
R&S ESU
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ALTernate<1|2>:ABSolute:STATe
ON | OFF
new function for
R&S ESU
R&S
ESU
FSE
CALCulate<1|2>:LIMit<1...8>:ACPower:
ALTernate<1|2>:RESult?
FSE
CALCulate<1|2>:LIMit<1...8>:ACPower:
ALTernate<1|2>:STATe
ON | OFF
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ALTernate<1|2>
[:RELative]:STATe of
R&S ESU
not available for FSET
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ALTernate<1|2>[:RELative]
0 to 100 DB,
0 to 100 DB
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ALTernate<1|2> of FSE
R&S
ESU
CALCulate<1|2>:LIMit<1...8>:ACPower:
ALTernate<1|2>[:RELative]:STATe
ON | OFF
compatible to
CALCulate<1|2>:
LIMit<1...8>:ACPower:
ALTernate<1|2>: STATe
of FSE
R&S
ESU
FSE
CALCulate<1|2>:LIMit<1...8>:ACPower[:STATe]
ON | OFF
Devices
Command
(Sheet 5 of 47)
Parameter
Notes
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...