R&S ESU
Remote Control – Description of Commands
CALCulate Subsystem
6.54
Operating Manual 1302.6163.12 - 03
CALCulate<1|2>:MARKer<1...4>:FUNCtion:NDBDown:RESult?
This command queries the frequency spacing (bandwidth) of the N-dB-down markers in the selected
measurement window. The numeric suffix <1...4> is irrelevant for this command.
A complete sweep with synchronization to sweep end must be performed between switching on the
function and querying the measured value in order to obtain a valid query result. This is only possible
in single-sweep mode.
Example:
"INIT:CONT OFF"
'Switches to single-sweep mode.
"CALC:MARK:FUNC:NDBD ON"
'Switches on the n-dB-down function in screen A.
"INIT;*WAI"
'Starts a sweep and waits for the end.
"CALC:MARK:FUNC:NDBD:RES?"
'Outputs the measured value of screen A.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
This command is only a query and therefore has no *RST value.
CALCulate<1|2>:MARKer<1...4>:FUNCtion:NDBDown:FREQuency?
This command queries the two frequencies of the N-dB-down marker in the selected measurement
window. The numeric suffix <1...4> is irrelevant for this command. The two frequency values are
separated by comma and output in ascending order.
A complete sweep with synchronization to sweep end must be performed between switching on the
function and querying the measured value to obtain a valid query result. This is only possible in single-
sweep mode.
Example:
"INIT:CONT OFF"
'Switches to single-sweep mode.
"CALC:MARK:FUNC:NDBD ON"
'Switches on the n-dB-down function in screen A.
"INIT;*WAI"
'Starts a sweep and waits for the end.
"CALC:MARK:FUNC:NDBD:FREQ?"
'Outputs the frequencies of the temporary markers in screen A.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A
This command is only a query and therefore has no *RST value.
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...