6.178
Operating Manual 1302.6163.12 - 03
[SENSe<1|2>:]FMEasurement:LISN[:TYPE]
TWOPhase | FOURphase | ESH3Z5 | ESH2Z5 |
ENV4200 | ENV216 | OFF
This command selects whether a V-network is driven automatically via the user port in the final
measurement and, if yes, which one:
Example:
":FME:LISN:TWOP"
Characteristics:
*RST value: OFF
SCPI: device-specific
Mode:
R
[SENSe<1|2>:]FMEasurement:LISN:PHASe
L1 | L2 | L3 | N[[,L1 | L2 | L3 | N],…]
This command selects the phases of the V-network on which level measurements are consecutively
performed in the final measurement. L2 and L3 are only available with four-line V-networks
(
FMEasurement:LISN FOURphase | ENV4200
).
Example:
":FME:LISN:PHAS L1,N"
Characteristics:
*RST value: L1
SCPI: device-specific
Mode:
R
[SENSe<1|2>:]FMEasurement:LISN:PEARth
GROunded | FLOating[,GROunded | FLOating]
This command selects the ground settings on the V-network on which level measurements are
consecutively performed in the final measurement. This command is available only for certain
V-networks (FMEasurement:LISN FOURphase | TWOPhase | ESH3Z5 | ESH2Z5).
Example:
":FME:LISN:PEAR GRO,FLO"
Characteristics:
*RST value: GRO
SCPI: device-specific
Mode:
R
[SENSe<1|2>:]FMEasurement:LISN:FILTer:HPAS[:STATe]
ON | OFF
This command selects the setting for the high pass on the V-network with which the level measurement
is performed in the final measurement. This command is available only for the R&S ENV 216 V-
network (FMEasurement:LISN ENV216).
Example:
":FME:LISN:FILT:HPAS ON"
Characteristics:
*RST value: ON
SCPI: device-specific
Mode:
R
TWOPhase and ESH3Z5
R&S ESH3-Z5 (two phases and protective earth are controllable)
FOURphase and ESH2Z5
R&S ESH2-Z5 (four phases and protective earth are controllable)
ENV4200
R&S ENV 4200 (four phases are controllable)
ENV216
R&S ENV 216 (two phases and highpass are controllable)
OFF Remote
control
deactivated
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...