Operating Manual 1302.6163.12 - 03
5.7
R&S ESU
Remote Control – Basics
Starting Remote Control
Via RS-232:
v24puts(port,"@LOC");
Set instrument to manual operation.
5.4.3.3
Restrictions
The following restrictions apply if the unit is remote-controlled via the RS-232-C
interface:
No interface messages, only control strings (see interface description in chapter
“Maintenance and Instrument Interfaces”
, section
Only the Common Commands *OPC? can be used for command synchronization,
*WAI and *OPC are not available.
Block data cannot be transmitted.
5.4.4
Remote Control in a Network (LAN Interface)
Via the LAN interface, the R&S ESU can be remotely controlled in a local area net-
work.
The LAN interface consists of a connector, a network interface card and protocols
(VXI-11 and RSIB). For details on the connector and its use refer to the Quick Start
Guide, chapter 1, "Front and Rear Panel".
Instrument access via VXI11 or RSIB is usually achieved from high level program-
ming platforms by using VISA as an intermediate abstraction layer. VISA encapsu-
lates the low level VXI, RSIB or even GPIB function calls and thus makes the
transport interface transparent for the user. The necessary VISA library is available
as a separate product. For details contact your local R&S sales representative.
5.4.4.1
Setting the Device Address
For control of the instrument in a network, it must be accessed using the preselected
IP address. The IP address of the instrument (device address) is defined in the net-
work configuration.
Setting the IP address:
1. Call
SETUP - GENERAL SETUP
–
CONFIGURE NETWORK
menu.
2. Select
Protocols
tab.
3. Under
Properties
, set IP address for TCP/IP protocol (for details refer to the Quick
Start Guide chapter
• Before the transition, command processing must be completed as otherwise
transition to remote control is performed immediately
• The keys can be enabled again by sending the control string "@LOC" via RS-
232 (see chapter
“Maintenance and Instrument Interfaces”
, section
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...