Operating Manual 1302.6163.12 - 03
4.59
R&S ESU
Receiver Mode
Meas Time -
Entry of measurement time
The measurement time can be set between 100 µs and 100 s separately for each
subrange. In the case of quasipeak weighting, the minimum is 1 ms. The measure-
ment time can be set independently for each scan range.
With option ESU-K53 (Time Domain Scan) the measurement time range depends
on the selected resolution bandwidth.
Remote command:
SCAN1:TIME 1ms
Auto Ranging -
Activates the autorange function
Remote command:
SCAN1:INP:ATT:AUTO OFF
RF Atten -
Entry of a fixed RF attenuation
The RF attenuation can be set separately for each subrange.
Remote command:
SCAN1:INP:ATT 10dB
Resolution
Bandwidth
Minimum
Measurement Time
Maximum
Measurement Time
10 Hz ... 50 Hz
10 ms
100 s
100 Hz ... 500 Hz
1 ms
100 s
1 kHz ... 30 kHz
100
µs
100 s
50 kHz
100
µs
50 s
100 kHz ...120 kHz
10
µs
30 s
200 kHz
10
µs
16 s
300 kHz
10
µs
10 s
500 kHz
10
µs
6 s
1 MHz
10
µs
3 s
If 0 dB RF attenuation is used with autoranging, care must be taken that the per-
missible signal level at the RF input is not exceeded.
Exceeding this level would damage the input mixer.
The 0 dB attenuation should under no circumstances be used when RFI voltage
measurements are performed with the aid of artificial networks as in this case very
high pulses occur during phase switching.
ON
R&S ESU automatically sets the input attenuation as a function of
the signal level.
OFF
The input attenuation setting of the scan table is used.
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...