Operating Manual 1302.6163.12 - 03
6.69
R&S ESU
Remote Control – Description of Commands
CALCulate Subsystem
CALCulate<1|2>:MARKer<1...4>:FUNCtion:POWer:RESult:PHZ
ON | OFF
This command switches the query response of the power measurement results in the indicated
measurement window between output of absolute values (OFF) and output referred to the
measurement bandwidth (ON).
The measurement results are output with
CALCulate:MARKer:FUNCtion:POWer:RESult?
Parameter:
ON:
Results output referred to measurement bandwidth.
OFF:
Results output in absolute values.
Example of channel/adjacent channel measurement:
If only the
channel power
is to be measured, all commands for defining the bandwidths of adjacent
channels as well as the channel spacings are not necessary. The number of adjacent channels is set
to 0 with
SENS2:POW:ACH:ACP 0
.
Characteristics:
*RST value: -
SCPI: device-specific
Mode:
A-F
"SENS2:POW:ACH:ACP 3"
'Sets the number of adjacent channels in screen B to 3.
"SENS2:POW:ACH:BAND 30KHZ"
'Sets the bandwidth of the main channel to 30 kHz.
"SENS2:POW:ACH:BAND:ACH 40KHZ"
'Sets the bandwidth of all adjacent channels to 40 kHz.
"SENS2:POW:ACH:BAND:ALT1 50KHZ"
'Sets the bandwidth of all alternate adjacent channels to
50 kHz.
"SENS2:POW:ACH:BAND:ALT2 60KHZ"
'Sets the bandwidth of alternate adjacent channel 2 to
60 kHz.
"SENS2:POW:ACH:SPAC 30KHZ"
'Sets the spacing between channel and adjacent chan-
nel as well as between all adjacent channels to 30 kHz.
"SENS2:POW:ACH:SPAC:ALT1 40KHZ"
'Sets the spacing between adjacent channel and alter-
nate adjacent channel as well as between all alternate
adjacent channels to 40 kHz.
"SENS2:POW:ACH:SPAC:ALT2 50KHZ"
'Sets the spacing between alternate adjacent channel 1
and alternate adjacent channel 2 to 50 kHz.
"SENS2:POW:ACH:MODE ABS"
'Switches on absolute power measurement.
"CALC2:MARK:FUNC:POW:SEL ACP"
'Switches the adjacent channel power measurement in
screen B.
"INIT:CONT OFF"
'Switches to single-sweep mode.
"INIT;*WAI"
'Starts a sweep and waits for the end.
"CALC2:MARK:FUNC:POW:RES:PHZ ON"
'Output of results referred to the channel bandwidth.
"CALC2:MARK:FUNC:POW:RES? ACP"
'Queries the result of the adjacent channel power mea-
surement in screen B referred to the channel bandwidth.
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...