Operating Manual 1302.6163.12 - 03
4.171
R&S ESU
Instrument Functions
Analyzer Mode
The
TIME DOM POWER
softkey activates the power measurement in the time
domain and opens a submenu for configuration of the power measurement.
The submenu allows selection of the type of power measurement (rms or mean
power), the settings for max hold and averaging as well as the definition of limits.
The power evaluation range can be limited by input of limit values.
POWER
ON | OFF
The
POWER ON/OFF
softkey switches the power measurement on and off. When
entering the submenu it is
ON
since the power measurement is already switched on
with the
TIME DOM POWER
softkey in the main menu.
Remote command:
CALC:MARK:FUNC:SUMM:PPE ON
CALC:MARK:FUNC:SUMM:PPE:RES?
CALC:MARK:FUNC:SUMM:RMS ON
CALC:MARK:FUNC:SUMM:RMS:RES?
CALC:MARK:FUNC:SUMM:MEAN ON
CALC:MARK:FUNC:SUMM:MEAN:RES?
CALC:MARK:FUNC:SUMM:SDEV ON
CALC:MARK:FUNC:SUMM:SDEV:RES?
PEAK
The
PEAK
softkey switches on the calculation of the peak value from the points of
the displayed trace or a segment thereof.
For the maximum peak, the largest peak value obtained since the activation of
MAX
HOLD ON
is displayed.
With
AVERAGE ON
, the peak values of a trace are averaged over several sweeps
and displayed.
The number of sweeps over which the average or the maximum value is calculated
is set with the
NUMBER OF SWEEPS
softkey.
Remote command:
CALC:MARK:FUNC:SUMM:PPE ONCALC:MARK:
FUNC:SUMM:PPE:RES?
RMS
The
RMS
softkey switches on the calculation of the rms value from the points of the
displayed trace or a segment of it.
For the maximum peak, the largest rms value obtained since the activation of
MAX
HOLD ON
is displayed.
With
AVERAGE ON
, the rms values of a trace are averaged over several sweeps
and displayed.
This softkey is only available in time domain (span = 0).
The measurement is performed on the trace on which marker 1 is placed. To eval-
uate another trace, marker 1 should be set on another trace using the
SELECT
TRACE
softkey in
MARKER
menu (
MKR
).
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...