Operating Manual 1302.6163.12 - 03
4.61
R&S ESU
Receiver Mode
DELETE
RANGE
The
DELETE RANGE
softkey clears the activated scan range. All other ranges are
shifted to the left by one column.
Remote command:
--
RANGES
1-5 | 6-10
With the
RANGES 1-5 | 6-10
softkey a switchover can be made between ranges 1-5
and 6-10.
Remote command:
--
FREQ AXIS
LIN | LOG
For details refer to
“FREQ AXIS LIN | LOG” on page 4.61
10dB MIN
ON | OFF
For details refer to
“10 DB MIN ON | OFF” on page 4.18
(
AMPT
menu).
RUN PRE-
SCAN+FINAL
For details refer to
“Triggering the Scan – TRIG Key” on page 4.63
.
RUN SCAN
For details refer to
USE CURR
SETTINGS
The
USE CURR SETTINGS
softkey
activates a scan which is performed using the
current receiver settings. The step size is automatically set with respect to the IF
bandwidth (Step Mode Auto). The start and stop frequency is set via the
FRE-
QUENCY
menu.
Remote command:
--
FIXED
FREQUENCY
The
FIXED FREQUENCY
softkey
activates time domain analysis.
The overall measurement time for time domain analysis can be defined in a data
entry field. The range is 10 µs to 10.000 s. The value entered is rounded to next inte-
ger that is a multiple of the measurement time of a single bar graph measurement.
The minimum value also depends on the set measurement time of a single bar
graph measurement and is at least twice this value.
Remote command:
FREQ:MODE CW
SCAN:TDOMain 100 s
SINGLE SCAN
Pressing the
SINGLE SCAN
softkey triggers a frequency scan. R&S ESU stops at
the end frequency.
The enhancement label SGL displayed at the screen edge indicates that the single-
scan mode is set.
Remote command:
:INIT2:CONT OFF
CONTINUOUS
SCAN
The
CONTINUOUS SCAN
softkey selects the continuous scan mode. R&S ESU
scans continuously until the scan is stopped.
Remote command:
:INIT2:CONT ON
FREQ AXIS
LIN | LOG
The
FREQ AXIS LIN | LOG
switches between linear and logarithmic frequency axis.
Default is LOG.
Remote command:
DISP:TRAC:X:SPAC LOG
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...