Operating Manual 1302.6163.12 - 03
6.155
R&S ESU
Remote Control – Description of Commands
SENSe Subsystem
6.16.2
SENSe:BANDwidth Subsystem
This subsystem controls the setting of the instrument's filter bandwidths. Both groups of commands
(BANDwidth and BWIDth) perform the same functions.
The measurement windows are selected by SENSe1 (screen A) and SENSe2 (screen B).
[SENSe<1|2>:]BANDwidth|BWIDth:FFT
WIDE | AUTO | NARROW
This command allows to specify between the following three options for FFT filters.
WIDE: The FFT filters with the greater partial span (this is the span which is covered with one FFT
analysis) are used always.
AUTO: The firmware decides whether to use wide or narrow filters to achieve the best performance of
the measurement.
NARROW: The FFT filters with the smaller partial span are used, this allows measurements near a
carrier with reduced reference level, because of a more narrow analog prefilter.
Example:
"BWID:FFT WIDE"
Characteristics:
*RST value: AUTO
SCPI: device-specific
Mode:
A
[SENSe<1|2>:]BANDwidth|BWIDth[:RESolution]
10 Hz to 10 MHz
This command defines the IF bandwidth or, in analyzer mode, the resolution bandwidth.
Analog resolution filters of 10 Hz to 10 MHz in 1, 2, 3, 5, 10 steps are available. These filters are
implemented as 5-circuit LC filters in the range from 300 kHz to 10 MHz and as digital filters with analog
characteristic in the range of 10 Hz to 100 kHz.
In addition, the EMI bandwidths 200 Hz, 9 kHz, and 120 kHz are available (6 dB bandwidths each).
The 1 MHz EMI bandwidth is the impulse bandwidth.
The EMI bandwidths are only available when parameter
PULSe
is selected by command
BAND:TYPE
.
FFT filters from 1 Hz to 30 kHz (3 dB bandwidth each) are also available in the frequency domain (span
> 0) for fast measurements on periodic signals. The instrument automatically switches to analog filters
above 30 kHz.
The FFT bandwidths are not available if the preselector is switched on.
A number of especially steep-edged channel filters can be selected provided that parameters
CFILter
or
RRC
are selected using the
BAND:TYPE
command. The possible combinations of filter
type and filter bandwidth are listed in the table "List of available channel filters" of chapter
, section
“Setting the Bandwidths and Sweep Time – BW Key” on page 4.111
If the resolution bandwidth is modified in analyzer mode, the coupling to the span is automatically
switched off.
If the resolution bandwidth is modified in FM demodulator mode, the coupling to the demodulation
bandwidth is automatically switched off.
Example:
"BAND 120 kHz"
'Sets the IF bandwidth to 120 kHz
Characteristics:
*RST value: - (AUTO is set to ON)
SCPI: conform
Mode:
R, A
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...