R&S ESU
Remote Control – Description of Commands
HCOPy Subsystem
6.118
Operating Manual 1302.6163.12 - 03
HCOPy:DEVice:LANGuage<1|2>
GDI | WMF | EWMF | BMP | HTML | PDF | RTF
This command determines the data format for the printed output.
Parameter:
GDI (Graphics Device Interface): Default format for output to a printer that has
been configured under Windows. Must be selected for output to the printer
interface (
HCOPy:DEVice 'SYST:COMM:PRIN'
). Can be used for output to a file
(
HCOPy:DEVice 'SYST:COMM:MMEM'
). The printer driver that was configured
under Windows is used to generate a file format that is specific to the printer. GDI
is available only for HCOPY:MODE SCReen.
WMF (WINDOWS Metafile) and EWMF (Enhanced Metafile Format): Data formats
for output to files which can be directly processed at a later point in time for
documentation purposes using suitable software. WMF can be used only for output
to a file (
HCOPy:DEVice 'SYST:COMM:MMEM'
), EWMF can also be used for
output to the clipboard (
HCOPy:DEVice 'SYST:COMM:CLIP'
).
BMP (Bitmap): Data format, exclusively for output to files (
HCOPy:DEVice
'SYST:COMM:MMEM'
).
BMP is available only for HCOPY:MODE SCReen.
HTML 4.0 (Hypertext Markup Language): Test reports can be exported to files in
HTML format. It is then possible to view these files using a web browser.
HTML is available only for HCOPY:MODE TREPort.
Adobe Acrobat (Portable Document Format): Test reports can be exported to files
in PDF format. These files can then be opened using a PDF reader such as Adobe
Acrobat.
PDF is available only for HCOPY:MODE TREPort.
Rich Text Format: Test reports can be exported to files in RTF format. It is then
possible to open these files for further processing using word processing software
such as Microsoft Word.
RTF is available only for HCOPY:MODE TREPort.
Example:
"HCOP:DEV:LANG WMF"
Characteristics:
*RST value: -
SCPI: conform
Mode:
R, A
HCOPy[:IMMediate<1|2>]
This command starts a hardcopy output. The numeric suffix selects which printer configuration (1 or 2)
is to be used for the hardcopy output. If there is no suffix, configuration 1 is automatically selected.
Example:
"HCOP"
"HCOPy:IMM1"
'Starts the hardcopy output to device 1 (default).
"HCOPy:IMM2"
'Starts the output to device 2.
Characteristics:
*RST value: -
SCPI: conform
Mode:
R, A
This command is an event and therefore has no *RST value and no query.
Summary of Contents for 1129.7246.03
Page 1: ...R S ESU EMI Test Receiver Operating Manual 1302 6163 12 03 Test Measurement Operating Manual ...
Page 25: ......
Page 27: ...R S ESU Putting into Operation 1 2 Operating Manual 1302 6163 12 03 ...
Page 29: ...R S ESU Getting Started 2 2 Operating Manual 1302 6163 12 03 ...
Page 31: ...R S ESU Manual Operation 3 2 Operating Manual 1302 6163 12 03 ...
Page 349: ...R S ESU Instrument Functions Basic Settings 4 318 Operating Manual 1302 6163 12 03 ...
Page 405: ...R S ESU Instrument Functions User Port 4 374 Operating Manual 1302 6163 12 03 ...
Page 439: ...R S ESU Remote Control Basics Status Reporting System 5 34 Operating Manual 1302 6163 12 03 ...
Page 841: ...R S ESU Error Messages Device Specific Messages 9 10 Operating Manual 1302 6163 12 03 ...
Page 854: ...Operating Manual 1302 6163 12 03 10 13 R S ESU ...
Page 855: ...R S ESU 10 14 Operating Manual 1302 6163 12 03 ...