2. SIGNALS AND WIRING
2 - 31
(b) Output device
Device Symbol
Connector
pin No.
Function and application
I/O
division
Control
mode
CP/BCD
CL
PS
Malfunction
ALM
CN1-48 When an alarm occurs, ALM will turn off.
When an alarm does not occur, ALM will turn on after 4 s to 5 s after
power-on.
When [Pr. PD34] is "_ _ 1 _", an alarming or warning will turn off ALM.
DO-1
Malfunction/War
ning
ALM
WNG
When an alarm occurs, ALMWNG will turn off.
When a warning (except [AL. 9F Battery warning]) occurs on and off will be
repeated every 1 s.
When an alarm/warning is not occurring, turning on the power will turn on
ALMWNG after 4 s to 5 s.
DO-1
Warning
WNG
When warning has occurred, WNG turns on. When a warning is not
occurring, turning on the power will turn off WNG after 4 s to 5 s.
DO-1
Battery warning
BWNG
BWNG turns on when [AL. 92 Battery cable disconnection warning] or [AL.
9F Battery warning] has occurred. When the battery warning is not
occurring, turning on the power will turn off BWNG after 4 s to 5 s.
DO-1
AL9F warning
BW9F
When [AL. 9F Battery warning] occurs, BW9F will turn on.
DO-1
Dynamic brake
interlock
DB
When using the signal, enable it by setting [Pr. PD23] to [Pr. PD26], [Pr.
PD28], and [Pr. PD47]. DB turns off when the dynamic brake needs to
operate. When using an external dynamic brake with the servo amplifier of
11 kW or more, this device is required. (Refer to "MR-J4-_A_(-RJ) Servo
Amplifier Instruction Manual" section 11.17.)
For the servo amplifier of 7 kW or less, it is not necessary to use this
device.
DO-1
Ready
RD
CN1-49 Enabling servo-on to make the servo amplifier ready to operate will turn on
RD.
DO-1
In-position
INP
CN1-24 When the number of droop pulses is in the preset in-position range, INP
will turn on. The in-position range can be changed using [Pr. PA10]. When
the in-position range is increased, INP may be on during low-speed
rotation.
INP turns on when servo-on turns on.
DO-1
Limiting torque
TLC
CN1-25 TLC turns on when a generated torque reaches a value set with any of [Pr.
PA11 Forward torque limit], [Pr. PA12 Reverse torque limit], or TLA
(Analog torque limit).
DO-1
Zero speed
detection
ZSP CN1-23
ZSP turns on when the servo motor speed is zero speed (50 r/min) or less.
Zero speed can be changed with [Pr. PC17].
OFF
ON
Servo motor
speed
20 r/min
(Hysteresis width)
[Pr. PC17]
20 r/min
(Hysteresis width)
OFF level
-70 r/min
ON level
-50 r/min
ON level
50 r/min
OFF level
70 r/min
0 r/min
[Pr. PC17]
ZSP
(Zero speed
detection)
1)
3)
2)
4)
Forward
rotation
direction
Reverse
rotation
direction
ZSP will turn on when the servo motor is decelerated to 50 r/min (at 1)),
and will turn off when the servo motor is accelerated to 70 r/min again (at
2)).
ZSP will turn on when the servo motor is decelerated again to 50 r/min (at
3)), and will turn off when the servo motor speed has reached -70 r/min (at
4)).
The range from the point when the servo motor speed has reached on
level, and ZSP turns on, to the point when it is accelerated again and has
reached off level is called hysteresis width.
Hysteresis width is 20 r/min for this servo amplifier.
DO-1
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...