2. SIGNALS AND WIRING
2 - 24
Device Symbol
Connector
pin No.
Function and application
I/O
division
Control
mode
CP/BCD
CL
PS
Operation mode
selection 1
MD0
CN1-16 Point table method/program method
Turning on MD0 will be automatic operation mode, off will be manual
operation mode. Changing an operation mode during operation will clear
the command remaining distance and the motor will decelerate to stop.
MD1 cannot be used.
Indexer method
Select an operation mode with combinations of MD0 and MD1. Refer to the
following table for combinations.
Changing an operation mode during operation will clear the command
remaining distance and the motor will decelerate to stop.
DI-1
Operation mode
selection 2
MD1
DI-1
Device
(Note)
Operation mode
MD1
MD0
0
0
Home position return mode
0
1
Manual operation mode
1 0
Automatic operation mode 1
(rotation direction specifying
indexer)
1 1
Automatic operation mode 2
(shortest rotating indexer)
Note.
0:
Off
1: On
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...