12. APPLICATION OF FUNCTIONS
12 - 45
4) Searching fails
Cam axis one cycle current value
Cam axis feed current value
(Feed current value)
When no feed current value that matched is found within one
cycle, the restoration fails.
Cam standard position
(b) Cam pattern of feed control
1) Searching from "Cam axis one cycle current value = 0" (Cam data start position = 0)
The cam axis one cycle current value is restored with
the first feed current value that matched.
(The cam axis one cycle current value is not restored
with the second and subsequent feed current values
that matched.)
Search from "Cam axis one cycle current value = 0".
Cam axis one cycle current value
Cam axis feed current value
(Feed current value)
Cam standard position
2) Searching from a value in the middle of the cam axis one cycle current value (Cam data start
position = 0)
Search from a value in the middle, and the cam
axis one cycle current value is restored with the
first feed current value that matched in the next
cycle.
The cam standard position is
automatically updated to the
one in the next cycle.
Cam axis one cycle current value (Initial setting)
Cam axis one cycle current value
Cam axis feed current value
(Feed current value)
Cam standard position at the
start of the restoration
New cam standard current value
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...