11. MR-D01 EXTENSION I/O UNIT
11 - 11
11.4 Installation direction and clearances
CAUTION
The equipment must be installed in the specified direction. Otherwise, it may
cause malfunction.
Leave specified clearances between the servo amplifier and cabinet walls or other
equipment. Otherwise, it may cause malfunction.
(1) Installation clearances of the servo amplifier
(a) Installation of one servo amplifier
40 mm
or more
10 mm
or more
10 mm
or more
(Note 2)
40 mm
or more
(Note 1)
Servo
amplifier
Cabinet
Cabinet
80 mm or more
Wiring allowance
Top
Bottom
Note 1. For the 11 kW to 22 kW servo amplifiers, the clearance between the bottom and the ground will be 120 mm or more.
2. When mounting MR-J4-500A-RJ, maintain a minimum clearance of 25 mm on the left side.