6. HOW TO USE INDEXER
6 - 23
(2) Timing chart
ON
OFF
ALM (Malfunction)
ON
OFF
MEND (Travel completion)
ON
OFF
Servo motor speed
Power supply
Forward rotation
0 r/min
Reverse rotation
ON
OFF
ON
OFF
ST1 (Forward rotation start)
SIG (External limit/Rotation direction
decision/Automatic speed selection)
Home position return completion flag
ON
OFF
ON
OFF
ON
OFF
MD0 (Operation mode selection 1)
MD1 (Operation mode selection 2)
Home position
shift distance
[Pr. PC01]
setting time
[Pr. PC02]
setting time
[Pr. PT39] setting time (Note 2)
5 ms or longer
Torque limit value of [Pr. PA11] and [Pr. PA12]
Torque limit value of [Pr. PC35]
Torque limit value
of [Pr. PC35]
In-position out of range
Station output 0
Station output 0
Creep speed
Home position return speed
PS0 (Station output 1) to
PS7 (Station output 8)
(Note 3)
Z-phase
Torque limit
Position where the station
home position shift distance
is added
5 ms or longer
Ignored (Note 1)
Note 1. When the rest of command travel distance is other than "0", turning on ST1 (Forward rotation start) will not be enabled.
2. Counting will start when the rest of command travel distance becomes "0".
3. For MR-J4-03A6-RJ servo amplifiers, up to six points of DO are available; therefore, PS0 to PS7 cannot be outputted
simultaneously.
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...