4. HOW TO USE THE POINT TABLE
4 - 28
2) Incremental value command method ([Pr. PT01] = _ _ _ 1)
Setting "1" to the auxiliary function executes positioning at the speed set in the following point
table.
At this time, the position data selected at start is valid, and the acceleration/deceleration time
constant set in the next and subsequent point tables is invalid.
By setting "1" to sub functions until point table No. 254, the operation can be performed at
maximum 255 speeds.
Always set "0" to the auxiliary function of the last point table.
To perform varying-speed operation, always set "0" to the dwell.
Setting "1" or more will enables the automatic continuous positioning operation.
The following table shows an example of setting.
Point table
No.
Dwell [ms]
(Note 1)
Auxiliary function
Varying-speed operation
1 0 1
Consecutive point table data
2 0 1
3
Disabled
0 (Note 2)
4 0 1
Consecutive point table data
5 0 1
6
Disabled
0 (Note 2)
Note 1. Always set "0".
2.
Always set "0" to the auxiliary function of the last point table among the
consecutive point tables.
The following shows an operation example with the set values listed in the table below.
Point table
No.
Position data
[10
STM
μ
m]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
(Note 1)
Auxiliary
function
M code
1 5.00
3000
100
150
0
1
05
2 3.00
2000
Disabled Disabled
0 1
10
3 2.00
1000
Disabled Disabled
0
1 15
4 6.00
500
Disabled Disabled
Disabled
0 (Note 2) 20
Note 1. Always set "0".
2.
Always set "0" to the auxiliary function of the last point table among the consecutive point tables.
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
Position address
Point table No. to select
ST1 (Forward rotation start)
ON
OFF
PT0 (Point table No. output 1)
to PT7 (Point table No. output 8)
(Note)
M code output
Speed
(3000)
Acceleration time constant
(100) of point table No. 1
Deceleration time constant
(150) of point table No. 1
Speed
(2000)
Speed
(1000)
6.00
0
5.00
8.00
10.00
1
1
05
Speed
(500)
5.00
3.00
2.00
16.00
Note. For MR-J4-03A6-RJ servo amplifiers, up to six points of DO are available; therefore, PT0 to PT7 cannot be outputted
simultaneously.
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...