3.2.5 Point table setting
POINT
Point table No. 1 to No. 99 can be set with the operation section of the servo
amplifier. To set point table No. 100 to No. 255, use MR Configurator2.
You can set the target position, servo motor speed, acceleration time constant, deceleration time constant,
dwell, auxiliary function and M code.
(1) Display transition
Target position
Servo motor speed
Deceleration time constant
Dwell
Auxiliary function
M code
Acceleration time constant
UP
DOWN
Point table No. 1
Point table transition
Point table No. 2
Point table No. 98
Point table No. 99
Point table No. 3
UP
DOWN
SET button
MODE button
Setting item transition