3. DISPLAY AND OPERATION SECTIONS
3 - 42
(3) Operation method
POINT
After changing and defining the setting values of the specified point table, the
defined setting values of the point table are displayed. To discard the changed
setting, press the "MODE" button for 2 s or more. The setting before the change
will be displayed. Keep pressing the "UP" or "DOWN" button to continuously
change the most significant digit of the setting values.
(a) Setting of 3 or less digits
The following example is the operation method at power-on to set "1" to the auxiliary function of the
point table No. 1.
……The setting value of auxiliary function of specified point table
No. flickers.
……During flickering, the set value can be changed.
Set using the "UP" or "DOWN" button.
Press the "MODE" button four times.
……A point table No. is displayed.
Press the "UP" or "DOWN" button to select
point table No. 1.
Press the "SET" button once.
Press the "UP" button five times.
Press the "SET" button twice.
Press the "UP" button once.
Press "SET" to enter.
To the next item setting
Press the "UP" or "DOWN" button to switch to other item of the same point table No.
Press the "MODE" button to switch to the next point table No.
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...