5. HOW TO USE THE PROGRAM
5 - 16
2) Program example 2
Using [Pr. PT23] to [Pr. PT25], you can switch off OUT1 (Program output 1) to OUT3 (Program
output 3) automatically.
Parameter Name
Setting
value
Description
Pr. PT23
OUT1 output setting
time
20
Switch off OUT1 200 [ms] later. a)
Pr. PT24
OUT2 output setting
time
10
Switch off OUT2 100 [ms] later. b)
Pr. PT25
OUT3 output setting
time
50
Switch off OUT3 500 [ms] later. c)
Command Description
SPN (500)
Servo motor speed
500 [r/min]
STA (200)
Acceleration time constant
200 [ms]
STB (300)
Deceleration time constant
300 [ms]
MOV (1000)
Absolute value travel command
1000 [×10
STM
μ
m]
OUTON (1)
Switch on OUT1 (Program output 1).
OUTON (2)
Switch on OUT2 (Program output 2).
OUTON (3)
Switch on OUT3 (Program output 3).
STOP Program
stop
ON
OFF
ON
OFF
ON
OFF
a) 200 ms
b) 100 ms
c) 500 ms
OUT1
(Program output 1)
OUT2
(Program output 2)
OUT3
(Program output 3)
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...