7. PARAMETERS
7 - 27
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP/BCD
CL
PS
PA18
*MTY
Servo motor
type setting
When using a linear servo motor, select any linear servo motor with [Pr. PA17] and
[Pr. PA18]. Set this and [Pr. PA17] at a time.
Refer to the table of [Pr. PA17] for settings.
This parameter is not available with MR-J4-03A6-RJ servo amplifiers.
0000h
PA19
*BLK
Parameter
writing inhibit
Select a reference range and writing range of the parameter.
To enable read/write the positioning control parameters ([Pr. PT_ _ ]), set [Pr. PA19] to
"0 0 A B" in the positioning mode.
Refer to table 7.4 for settings.
Linear servo motor/DD motor setting parameters ([Pr. PL_ _ ]) cannot be used with
MR-J4-03A6-RJ servo amplifiers.
00AAh
Table 7.4 [Pr. PA19] setting value and reading/writing range
PA19
Setting
operation
PA PB PC PD PE PF PL Po PT
Other
than
below
Reading
Writing
000Ah
Reading
Only
19
Writing
Only
19
000Bh
Reading
Writing
000Ch
Reading
Writing
00AAh
(initial
value)
Reading
Writing
00ABh
Reading
Writing
100Bh
Reading
Writing
Only
19
100Ch
Reading
Writing
Only
19
10AAh
Reading
Writing
Only
19
10ABh
Reading
Writing
Only
19
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...