5. HOW TO USE THE PROGRAM
5 - 17
3) Program example 3
When setting the position address where the "OUTON" or "OUTOF" command is executed by
using the "TRIP" or "TRIPI" command
Command Description
SPN (1000)
Servo motor speed
1000 [r/min]
STA (200)
Acceleration time constant
200 [ms]
STB (300)
Deceleration time constant
300 [ms]
MOV (500)
Absolute value travel command
500 [×10
STM
μ
m]
TRIP (250)
Absolute value trip point specification 250 [×10
STM
μ
m] a)
OUTON (2)
Switch on OUT2 (Program output 2).
b)
TRIP (400)
Absolute value trip point specification 400 [×10
STM
μ
m] c)
OUTOF (2)
Switch off OUT2 (Program output 2).
d)
TIM (100)
Dwell
100 [ms]
MOVI (500)
Incremental value travel command
500 [×10
STM
μ
m]
TRIPI (300)
Incremental value trip point
specification
300 [×10
STM
μ
m] e)
OUTON (2)
Switch on OUT2 (Program output 2).
f)
STOP Program
stop
g)
a) 250 × 10
STM
μ
m
ON
OFF
OUT2
(Program output 2)
100 ms
e) 300 × 10
STM
μ
m
c) 400 × 10
STM
μ
m
b)
d)
f)
g)
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...