3. DISPLAY AND OPERATION SECTIONS
3 - 14
Name Display Description
Software version - Lower
Indicates the version of the software.
Software version - Upper
Indicates the system number of the software.
Automatic VC offset (Note)
If offset voltages in the analog circuits inside and
outside the servo amplifier cause the servo motor
setting speed not to be the designated value at VC
or OVC of 0 V, a zero-adjustment of offset voltages
will be automatically performed. When using the VC
automatic offset, enable it in the following
procedures.
1) Press the "SET" once.
2) Set the number in the first digit to 1 with
"UP"/"DOWN".
3) Press the "SET".
This function cannot be used if the input voltage of
VC or OVC is -0.4 V or less, or +0.4 V or more.
When the VC automatic offset is enabled, the
following automatic offset voltage is applied
according to the setting of [Pr. Po11].
Pr. Po11
Offset voltage to be
automatically adjusted
_ _ 0 _
Offset voltage set with [Pr. PC37]
(Servo amplifier side)
_ _ 1 _
Offset voltage set with [Pr. Po21]
(MR-D01 side)
Servo motor series ID
Push the "SET" button to show the series ID of the
servo motor currently connected.
For indication details, refer to app. 1 of "Servo Motor
Instruction Manual (Vol. 3)".
Servo motor type ID
Push the "SET" button to show the type ID of the
servo motor currently connected.
For indication details, refer to app. 1 of "Servo Motor
Instruction Manual (Vol. 3)".
Servo motor encoder ID
Push the "SET" button to show the encoder ID of
the servo motor currently connected.
For indication details, refer to app. 1 of "Servo Motor
Instruction Manual (Vol. 3)".
For manufacturer adjustment
This is for manufacturer adjustment.
For manufacturer adjustment
This is for manufacturer adjustment.
Teaching function
Refer to section 3.1.10.
After an operation travels to a target position
(MEND (Travel completion) is turned on) with a JOG
operation or manual pulse generator operation,
pushing the "SET" button of the operation part or
turning on TCH (Teach) will import position data.
This function is available only in the point table
method. For other control mode, the display remains
the same.
Note. Even if VC automatic offset is performed and 0 V is inputted, the speed may not completely be the set value.
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...