7. PARAMETERS
7 - 40
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP/BCD
CL
PS
PB51
NHQ5
Notch shape
selection 5
Set forms of the machine resonance suppression filter 5.
When you select "Enabled (_ _ _ 1)" of "Robust filter selection" in [Pr. PE41], the machine resonance suppression filter
5 is not available.
_ _ _ x Machine resonance suppression filter 5 selection
0: Disabled
1: Enabled
0h
_ _ x _ Notch depth selection
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
0h
_ x _ _ Notch width selection
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
0h
x _ _ _ For manufacturer setting
0h
PB52
VRF21
Vibration
suppression
control 2 -
Vibration
frequency
Set the vibration frequency for vibration suppression control 2 to suppress
low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB53
VRF22
Vibration
suppression
control 2 -
Resonance
frequency
Set the resonance frequency for vibration suppression control 2 to suppress
low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.1 to 300.0
100.0
[Hz]
PB54
VRF23
Vibration
suppression
control 2 -
Vibration
frequency
damping
Set a damping of the vibration frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
PB55
VRF24
Vibration
suppression
control 2 -
Resonance
frequency
damping
Set a damping of the resonance frequency for vibration suppression control 2 to
suppress low-frequency machine vibration.
When "Vibration suppression control 2 tuning mode selection" is set to "Automatic
setting (_ _ 1 _)" in [Pr. PB02], this parameter will be set automatically. When "Manual
setting (_ _ 2 _)" is selected, the setting written to the parameter is used.
To enable the setting value, set "Vibration suppression mode selection" to "3 inertia
mode (_ _ _ 1)" in [Pr. PA24].
Setting range: 0.00 to 0.30
0.00
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...