5. HOW TO USE THE PROGRAM
5 - 11
3) Program example 3
Using the S-pattern acceleration/deceleration time constants reduces abrupt movements at
acceleration or deceleration. When the "STD" command is used, [Pr. PC03 S-pattern
acceleration/deceleration time constant] does not function.
Command Description
SPN (1000)
Servo motor speed
1000 [r/min]
a)
STC (100)
Acceleration/deceleration time
constant
1000 [ms]
b)
STD (10)
S-pattern acceleration/deceleration
time constant
10 [ms]
c)
MOV (2000)
Absolute value travel command
2000 [×10
STM
μ
m] d)
STOP Program
stop
c)
c)
c)
a) Servo motor speed
(1000 r/min)
b) Acceleration/deceleration
time constant (1000 ms)
b) Acceleration/deceleration
time constant (1000 ms)
d) Absolute value travel command
(2000 × 10
STM
μ
m)
c) S-pattern acceleration/
deceleration time constant
(10 ms)
Servo motor
speed
Forward rotation
0 r/min
Reverse rotation
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...