3. DISPLAY AND OPERATION SECTIONS
3 - 38
3.2.4 Alarm mode
The current alarm, past alarm history, and parameter error are displayed. The alarm number that has
occurred or the parameter numbers in error are displayed on the display.
Name
Display (Note 1)
Description
Current alarm
Indicates no occurrence of an alarm.
2 s
interval
Indicates the occurrence of [AL. 33.1 Main
circuit voltage error].
Flickers at alarm occurrence.
The alarm number and detail number are
displayed alternately by intervals of 2 s.
Alarm history
"SET"
Indicates that the last alarm is [AL. 50.1
Thermal overload error 1 during operation].
When an alarm is recorded to alarm history,
the second digit decimal point flickers.
Press the "SET" button to display the detail
number of [AL. 50].
"SET"
Indicates the second last alarm is [AL. 33.1
Main circuit voltage error].
When an alarm is recorded to alarm history,
the second digit decimal point flickers.
Press the "SET" button to display the detail
number of [AL. 33].
"SET"
"SET"
Indicates that there is no third alarm in the
past.
If there is no alarm history, the display will be
as shown as in the left, when the "SET"
button is pressed.
Indicates that there is no sixteenth alarm in
the past.
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...