5. HOW TO USE THE PROGRAM
5 - 23
(f) External pulse count (COUNT)
When the number of input pulses of the manual pulse generator becomes larger than the value set
for the "COUNT" command, the next step is executed. Setting "0" clears cumulative input pulses.
Command Description
COUNT (500)
Wait for the next step until the number of input pulses of the manual pulse generator reaches 500
[pulse]. a)
SPN (500)
Servo motor speed
500 [r/min]
STA (200)
Acceleration time constant
200 [ms]
STB (300)
Deceleration time constant
300 [ms]
MOV (1000)
Absolute value travel command
1000 [×10
STM
μ
m]
TRIP (500)
Trip point specification
500 [×10
STM
μ
m] b)
COUNT (0)
Clear cumulative input pulses.
c)
STOP Program
stop
c) Clear cumulative input pulses.
b) 500 [×10
STM
μ
m]
Manual pulse generator
Cumulative input pulses
a) 500 [pulse]
Servo motor speed
Forward rotation
0 r/min
Reverse rotation
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...