11. MR-D01 EXTENSION I/O UNIT
11 - 10
Note 1. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using the power factor improving DC reactor, short P3 and P4.
2.
A 1-phase 200 V AC to 240 V AC power supply may be used with the servo amplifier of MR-J4-70A-RJ or less. For 1-phase
200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. For power supply specifications, refer to
section 1.3 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual".
3. Depending on the main circuit voltage and operation pattern, a bus voltage may drop, causing dynamic brake deceleration
during forced stop deceleration. When dynamic brake deceleration is not required, delay the time to turn off the magnetic
contactor.
4. When using an MR-J4-_A-RJ servo amplifier in the linear servo system or in the fully closed loop system, connect an external
encoder to this connector. Refer to Table 1.1 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual" and "Linear Encoder
Instruction Manual" for the compatible external encoders.
5.
Always connect between P+ and D terminals. When using the regenerative option, refer to section 11.2 of "MR-J4-_A_(-RJ)
Servo Amplifier Instruction Manual".
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...