7. PARAMETERS
7 - 52
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
Control mode
CP/BCD
CL
PS
PC45
*COPA
Function
selection C-A
_ _ _ x Encoder pulse count polarity selection
Select a polarity of the linear encoder or load-side encoder.
0: Encoder pulse increasing direction in the servo motor CCW or positive direction
1: Encoder pulse decreasing direction in the servo motor CCW or positive direction
This digit is not available with MR-J4-03A6-RJ servo amplifiers.
0h
_ _ x _ For manufacturer setting
0h
_ x _ _ Selection of A/B/Z-phase input interface encoder Z-phase connection judgment
function
Select the non-signal detection status for the pulse train signal from the A/B/Z-phase
input interface encoder used as a linear encoder or load-side encoder.
This function is enabled only when you use an A/B/Z-phase input interface encoder.
This digit is not available with MR-J4-03A6-RJ servo amplifiers.
0h
Setting
value
Detection of
disconnection
Alarm status
Z-phase-side
non-signal
Full. Lin.
_ 0 _ _
Enabled
[AL. 71.6]
(Z-phase)
[AL. 20.6]
(Z-phase)
_ 1 _ _
Disabled
x _ _ _ For manufacturer setting
0h
PC51
RSBR
Forced stop
deceleration
time constant
Set a deceleration time constant when you use the forced stop deceleration function.
Set the time per ms from the rated speed to 0 r/min or 0 mm/s.
Setting "0" will be 100 ms.
Forced stop deceleration
[Pr. PC51]
0 r/min
Servo motor speed
Rated speed
Dynamic brake
deceleration
(Linear servo
motor speed)
(0 mm/s)
[Precautions]
If the servo motor torque or linear servo motor thrust is saturated at the maximum
value during forced stop deceleration because the set time is too short, the time to
stop will be longer than the set time constant.
[AL. 50 Overload alarm 1] or [AL. 51 Overload alarm 2] may occur during forced
stop deceleration, depending on the set value.
After an alarm that leads to a forced stop deceleration, if an alarm that does not lead
to a forced stop deceleration occurs or if the control circuit power supply is cut,
dynamic braking will start regardless of the deceleration time constant setting.
Setting range: 0 to 20000
100
[ms]
www.kavrammuhendislik.com.tr
Summary of Contents for MELSERVO MR-J4-03A6-RJ
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO www kavrammuhendislik com tr ...
Page 127: ...3 DISPLAY AND OPERATION SECTIONS 3 54 MEMO www kavrammuhendislik com tr ...
Page 275: ...5 HOW TO USE THE PROGRAM 5 68 MEMO www kavrammuhendislik com tr ...
Page 305: ...6 HOW TO USE INDEXER 6 30 MEMO www kavrammuhendislik com tr ...
Page 405: ...7 PARAMETERS 7 100 MEMO www kavrammuhendislik com tr ...
Page 419: ...8 TROUBLESHOOTING 8 14 MEMO www kavrammuhendislik com tr ...
Page 423: ...9 OPTIONS AND PERIPHERAL EQUIPMENT 9 4 MEMO www kavrammuhendislik com tr ...
Page 607: ...MEMO www kavrammuhendislik com tr ...