201
────────────────────────────────────────────────────
12.5 Command Summary
────────────────────────────────────────────────────
[ch]: channel no. / [No.]: number of items
Command
Data format
( ):
number of data items
Explanation
Page
:INTEGrate:RESEt
Resets the integration value.
167
:INTEGrate:STARt
:INTEGrate:STOP
NR1 numerical data (6)
NR1 numerical data (6)
Starts the integration.
Stops integration.
167
:INTEGrate?
Queries the start channles currently
operating integration.
168
:INTERval:CONTrol
:INTERval:CONTrol?
ON/OFF
Enables and disables the interval time
control.
Queries the interval time control.
168
:INTERval:TIME
:INTERval:TIME?
NR1 numerical data (3)
Sets the interval time.
Queries the interval time.
168
:INTERval?
Queries the interval time control.
169
:KEYLock
:KEYLock?
ON/OFF
Enables of disables key lock.
Queries the current setting of key lock.
169
:LANGuage
:LANGuase?
Character data
Sets the language to be displayed.
Queries the language to be displayed.
169
170
:LPF[ch]
:LPF[ch]?
NRf numerical data (1)
Sets the low-pass filter
Queries the low-pass filter
170
:MATH
:MATH?
NR1 numerical data (1)
Sets the calculation.
Queries the calculation.
170
171
:MEASure:ITEM
:MEASure:ITEM?
Character data (35)
Specify the default items to be
transferred.
Queries the data output items.
171
:MEASure:ITEM:ALLClear
Clears all default items to be transferred.
171
:MEASure:ITEM:EFFiciency
:MEASure:ITEM:EFFiciency?
NR1 numerical data (1)
Sets the output data of efficiency
measurement value.
Queries the output data of efficiency
measurement value.
172
:MEASure:ITEM:EXTernalin
:MEASure:ITEM:EXTernalin?
NR1 numerical data (1)
Sets the output data of external signal
input.
Queries the output data of external signal
input.
172
173
:MEASure:ITEM:FREQuency
:MEASure:ITEM:FREQuency?
NR1 numerical data (1)
Sets the frequency output data.
Queries the frequency output data.
173
:MEASure:ITEM:INTEGrate
:MEASure:ITEM:INTEGrate?
NR1 numerical data (10) Sets the output item for integration.
Queries the output item for integration.
174
:MEASure:ITEM:LOADfactor
:MEASure:ITEM:LOADfactor?
NR1 numerical data (2)
Sets the output item for the load factor.
Queries the output item for the load
factor?
175
:MEASure:ITEM:NORMal
:MEASure:ITEM:NORMal?
NR1 numerical data (8)
Sets the output item for the normal
measurement.
Queries the output item for the normal
measurement.
176
:MEASure:ITEM:SUM
:MEASure:ITEM:SUM?
NR1 numerical data (7)
Sets the output item for the SUM value.
Queries the output item for the SUM
value.
177
:MEASure?
Character data (70)
Queries the specified data.
178
Summary of Contents for Power HiTester 3193
Page 2: ......
Page 50: ...32 3 9 Operations During Power Failure ...
Page 76: ...58 4 13 Degaussing ...
Page 80: ...62 5 2 Setting the Frequency Range fa ...
Page 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Page 112: ...94 10 3 Output Rate ...
Page 250: ...232 13 9 Error and Overflow Displays ...
Page 278: ...260 17 5 Internal Block Diagram ...
Page 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Page 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Page 306: ...INDEX 4 Index ...
Page 307: ......
Page 308: ......
Page 309: ......