20.1 General Specifications
────────────────────────────────────────────────────
Measurement items
When using the optional units; 9600, 9601, 9602:
Voltage (
U
), current (
I
), active power (
P
), apparent power (
S
), reactive
power (
Q
), power factor (
λ
), phase angle (
φ
), frequency (
f
), current
integration (
Ih
), power integration (
WP
), efficiency (
η
), load factor (
LF
)
When using the optional unit; 9603:
(input the analog output from the external device and set the scaling and
units)
Voltage (V), torque (N
・
m,mN
・
m,kN
・
m,kgf
・
m,kgf
・
cm), number of rotating
(rpm), frequency (Hz), motor power (
P
m,
W
)
When using the optional unit; 9605:
Harmonic waveform (
U
,
I
,
P
)
,
waveform (
U
,
I
)
,
Voltage fluctuation/ flicker
measurement function
Screen display
6.4-inch TFT color LCD (640
×
480 dots)
Display resolution
99999 counts (excluding integration) (0.0000p to 99999T)
9999999 counts (integration) (0 to 9999999T)
Display range
Depends on the specifications of the input unit combined
Display update rate
8 times/s max (when using the 9605, depends on the specifications of the
9605)
Analog output
U
,
I
,
P
and
V
a,
V
b from each units (20 items max)
Monitor output
U
,
I
from each units (12 items max)
External control
External A/D trigger (for display update during holding displays)
Integration start and stop
Integration reset
For FDD/printer control (start)
Control signal for the 9605
Control signal
Controlled by 0/5 V logic signal or open/short circuit
Real-time clock accuracy
±
25 ppm
±
1 second (25
o
C)
Dielectric strength
Using with the 9600 and 9601: 5.55 kV AC for 1 minute (sensitive current
1 mA)
(between
U
and
I
input terminals and case, between
U
and
I
input
terminals and power plug)
Using with the 9602: 5.55 kV AC for 1 minute (sensitive current 1 mA)
(between
U
input terminal and sensor input terminal, between
U
input
terminal and case, between
U
input terminal and power plug)
Maximum rated voltage to
earth
Using with the 9600 and 9601
Voltage input terminal, Current input terminal
600 V measurement category III (expected transient overvoltage: 6000 V)
1000 V measurement category II (expected transient overvoltage: 6000 V)
Using with the 9602
Voltage input terminal
600 V measurement category III (expected transient overvoltage: 6000 V)
Rated supply voltage
100 V/ 120 V/ 200 V/ 230 V (auto-switching, account to 10%),
50/60 Hz (Voltage fluctuations of
±
10% from the rated supply voltage are
taken into account.)
(anticipated transient overvoltage 2500 V)
Rated power
150 VA max
External dimensions
Approx.430W
×
150H
×
370D mm, 16.93"W
×
5.91"H
×
14.57"D
(excluding protrusions)
Mass
Approx.13 kg, 458.6 oz.
(during installing the 9600 (6 channels), 9603, and 9604)
Accessories
Instruction manual
Power cord
Connector
Product warranty period
3 years
Summary of Contents for Power HiTester 3193
Page 2: ......
Page 50: ...32 3 9 Operations During Power Failure ...
Page 76: ...58 4 13 Degaussing ...
Page 80: ...62 5 2 Setting the Frequency Range fa ...
Page 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Page 112: ...94 10 3 Output Rate ...
Page 250: ...232 13 9 Error and Overflow Displays ...
Page 278: ...260 17 5 Internal Block Diagram ...
Page 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Page 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Page 306: ...INDEX 4 Index ...
Page 307: ......
Page 308: ......
Page 309: ......
Page 310: ......