135
────────────────────────────────────────────────────
*ESEF?
────────────────────────────────────────────────────
Syntax
*ESEF?
Response
syntax
Same as *ESEF
(Headers: ON) (Headers: OFF)
*ESEF
<NR1> <NR1>
Example
Transmission
Response
*ESEF?
*ESEF 6
6
Syntax
*ESR?
Response
syntax
*ESR
<NR1>
<NR1> = 0 to 255
Example
Transmission
Response
*ESR?
*ESR 32
Indicates command error occurs.
(bit5 corresponds to CME.)
Syntax
*ESR0?
Response
syntax
*ESR0
<NR1>
<NR1> = 0 to 255
Example
Transmission
Response
*ESR0?
*ESR0 16
Indicates FDD error occurs.
Syntax
*ESR1?
Response
syntax
*ESR1
<NR1>
<NR1> = 0 to 255
Example
Transmission
Response
(Header on) (Header off)
*ESR1?
*ESR1 14
14
Indicates out-of-range inputs for
channel 1, 2, and 3.
Function
The contents of the event status enable
register F (ESERF) as set by the
*
ESEF
command are returned as a NR1 value (0
to 255).
Error
Query error / If the response message is
longer than 2000 bytes
Function
The contents of SESR are returned as
NR1 value (0 to 255).
128
64
32
16
8
4
2
1
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
PON URQ CME EXE
DDE QYE RQC OPC
Function
The contents of ESR0 are returned as
NR1 value (0 to 255).
128
64
32
16
8
4
2
1
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
SE
ST
PE
FE
SP
IE
CE
Function
The contents of ESR1 are returned as
NR1 value (0 to 255).
Unless the contents of input unit for each
bits are read, they are not cleared.
128
64
32
16
8
4
2
1
bit 7 bit 6 bit 5 bit 4 bit 3 bit 2 bit 1 bit 0
O6
O5
O4
O3
O2
O1
OF
Error
Query error / If the response message is
longer than 2000 bytes
*ESEF?
Queries the standard event status enable register F (SESERF).
*ESR?
Queries out and clears the contents of the standard event status register (SESR).
*ESR0?
Queries event status register 0 (ESR0).
*ESR1?
Queries event status register 1 (ESR1).
Summary of Contents for Power HiTester 3193
Page 2: ......
Page 50: ...32 3 9 Operations During Power Failure ...
Page 76: ...58 4 13 Degaussing ...
Page 80: ...62 5 2 Setting the Frequency Range fa ...
Page 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Page 112: ...94 10 3 Output Rate ...
Page 250: ...232 13 9 Error and Overflow Displays ...
Page 278: ...260 17 5 Internal Block Diagram ...
Page 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Page 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Page 306: ...INDEX 4 Index ...
Page 307: ......
Page 308: ......
Page 309: ......
Page 310: ......