157
────────────────────────────────────────────────────
:DISPlay:DETail [channel no.]
────────────────────────────────────────────────────
Syntax
:DISPlay:DETail
[1 - 6] <A>, ..
Example
When measuring in 3V3A mode with
using the channels 1 to 3 of the input
unit.
:DISPLAY:DETail1 U1,U2,U3,U123,
I1,I2,I3,I123,P123,PF123,FA
Sets the display item to U1, U2, U3,
U123, I1, I2, I3, I123, P123, PF123
(power factor
λ
123),FA (frequency
measurement) on the detail display for
channels 1 to 3.
Connection
mode
Display items on details screen
1P2W
[10]
U
n
, I
n
, P
n
, PK
n
, S
n
, Q
n
, PF
n
, DEG
n
,
FA, FB, FC
1P3W
3P3W
[23]
U
n
1
, U
n
2
, U
n
1
n
2
, I
n
1
, I
n
2
, I
n
1
n
2
,
P
n
1
, P
n
2
, P
n
1
n
2
, PK
n
1
, PK
n
2
,
S
n
1
, S
n
2
, S
n
1
n
2
, Q
n
1
, Q
n
2
, Q
n
1
n
2
,
PF
n
1
, PF
n
2
, PF
n
1
n
2
/DEG
n
1
, DEG
n
2
, DEG
n
1
n
2
,
FA, FB, FC
3V3A
3P4W
[30]
U
n
1
, U
n
2
, U
n
3
, U
n
1
n
2
n
3
, I
n
1
, I
n
2
, I
n
3
, I
n
1
n
2
n
3
,
P
n
1
, P
n
2
, P
n
3
, P
n
1
n
2
n
3
, PK
n
1
, PK
n
2
, PK
n
3
,
S
n
1
, S
n
2
, S
n
3
, S
n
1
n
2
n
3
, Q
n
1
, Q
n
2
, Q
n
1
n
2
n
3
,
PF
n
1
, PF
n
2
, PF
n
3
, PF
n
1
n
2
n
3
/DEG
n
1
, DEG
n
2
,
DEG
n
3
, DEG
n
1
n
2
n
3
, FA, FB, FC
[ ]: maximum number of items
n
: channel 1 to 6
n
1
n
2
: channels 1 and 2, 3 and 4, 4 and 5, or 5 and 6
n
1
n
2
n
3
: channels 1, 2, and 3, or 4, 5 and 6
Syntax
:DISPlay:DETail
[1 - 6]
?
Response
syntax
:DISPLAY:DETAIL
[1 - 6] <A>
Example
Transmission
Response
:DISPLAY:DETAIL1?
:DISPLAY:DETAIL1 U1,U2,U3,U123,
I1,I2,I3,I123,P123,PF123,FA
Function
Set items to be displayed on the "Detail
display" screen of the specified channel
screen, and select screen display.
Errors
Execution error / If the setting data is
other than character data.
Note
・
For the detail screen for is 1P3W or
above, for the channel specification enter
the number of the lowest-numbered
channel in the combination. For example,
when using input unit channels 1 to 3 in
3P3W mode, specify "1".
・
The number of character data
<
A
>
which
can be specified varies depending on the
connection mode. The position for
display cannot be specified since the
position has been fixed.
・
If the setting exceeds maximum number
of set item, the data exceeded is ignored.
・
When "Pk" (waveform peak value) is
specified, the peak value which is set by
the :WAVEPeak[ch] command (switching
voltage/current) is displayed.
・
"PF" (power factor
λ
) and "DEG"
(phase angle
φ
) cannot be displayed
simultaneously. If set both, the latter is
displayed.
Function
Queries items to be displayed on the
"Detail display" screen of the channel
screen.
Note
For the detail screen for is 1P3W or
above, for the channel specification enter
the number of the lowest-numbered
channel in the combination. For example,
when using input unit channels 1 to 3 in
3P4W mode, specify "1".
:DISPlay:DETail [
channel no.
]
Set items to be displayed on the "Detail display" screen of the channel screen.
:DISPlay:DETail [
channel no.
]?
Queries items to be displayed on the "Detail display" screen for the specified channel.
Summary of Contents for Power HiTester 3193
Page 2: ......
Page 50: ...32 3 9 Operations During Power Failure ...
Page 76: ...58 4 13 Degaussing ...
Page 80: ...62 5 2 Setting the Frequency Range fa ...
Page 108: ...90 9 3 Internal Circuit for the External Control and Timing ...
Page 112: ...94 10 3 Output Rate ...
Page 250: ...232 13 9 Error and Overflow Displays ...
Page 278: ...260 17 5 Internal Block Diagram ...
Page 284: ...266 19 2 Installation Procedures For JIS standard For EIA standard External Dimensions ...
Page 300: ...282 20 4 Internal Block Diagram of the 3193 ...
Page 306: ...INDEX 4 Index ...
Page 307: ......
Page 308: ......
Page 309: ......
Page 310: ......