background image

A/C AIR LAUNCHER

TM

 

Operating Instructions 

 

 

 

P/N 101050 (120 VAC) 
P/N 101051 (230 VAC) 

 

Summary of Contents for A/C Air Launcher 101050

Page 1: ...A C AIR LAUNCHERTM Operating Instructions P N 101050 120 VAC P N 101051 230 VAC ...

Page 2: ...new product is quite extensive To guarantee perfect and successful work with this machine please take some time to read the manual carefully And finally we believe you will enjoy years of great effects if you care for and maintain your A C AIR LAUNCHERTM CITC 1420 80TH SW D EVERETT WA 98203 888 786 CITC www citcfx com ...

Page 3: ...4 Description 4 5 Safety Instructions 4 6 Operating the A C AIR LAUNCHERTM 5 6 1 Assembly 6 2 Loading 6 3 Optional backpressure cap 6 4 Pressurizing the tank 6 5 Firing the A C Air LauncherTM 6 6 Troubleshooting 7 Service and Maintenance 7 8 Technical Data 7 9 Limited Warranty Conditions 8 ...

Page 4: ...tock Custom mix by request Tissue Confetti Multicolor or solid colors 5 8 x 2 1 4 1 6cm x 5 7cm P N 255501 Mylar Tissue Confetti Silver or gold Mylar color tissue 5 8 x 2 1 4 1 6cm x 5 7cm P N 255651 STREAMERS SPEED LOAD FlameProof Biodegradeable Tissue Paper Mylar 1 x 20 2 5cm x 51cm soft sleeve for quick loading of your cannons slide in then remove sleeve no packing Tissue Streamer 1 2 x 30 1 3c...

Page 5: ...an electric release solenoid valve 1 2 high volume type The launcher fires as soon as it is plugged in or if connected to an electrical switchbox as soon as it is switched on Launcher comes with a 24VAC solenoid valve and 120VAC 240VAC 24V transformer 5 Safety instructions WARNING Read and understand all labels and operating instructions before attempting installation o Inspect all equipment and b...

Page 6: ...streamers The more you include the more spectacular the effect If your budget allows using 120 rolls looks great If you want an unbelievable effect use 240 rolls You may fill the unit to the top if you wish or just load it to full Outdoors or large arenas the bigger and heavier streamers will travel further For the highest altitude and the best visual effect load at least 36 of the 30 streamers Wa...

Page 7: ...ns This unit is equipped with a 120VAC 240VAC 24VAC transformer P N 600670 to actuate the solenoid and this will release the air pressure Plug the transformer into the corresponding outlet that is controlled with an off on switch The solenoid valve opens if there is power to the transformer so always have the switch off until ready to shoot the product into the air Use of a momentary switch is rec...

Page 8: ... service It is a good practice to test the solenoid valve with a charge of air before loading the barrel When finished with use Remove and inspect barrel for cracks Check that cord is in good condition not pinched or broken 8 Technical Data A C Air LauncherTM Technical Data P N 101050 230VAC P N 101051 Dimensions Assembled 35 x 34 x 14 89 cm x 86 cm x 36 cm Weight 20 lb 9 kg Shipping Weight 27 lb ...

Page 9: ...dification is not covered by this warranty Using any fluid other than what is recommended for this machine will void warranty No liability is accepted for injury or for loss damage or expense resulting from any interruption whatsoever in the operation of the product or from any consequential loss arising there from No liability is accepted for normal wear and tear We wish to satisfy YOU our custom...

Page 10: ...eight costs to and from CITC when under the limited warranty services are the responsibility of the customer Customer must place appropriate insurance on return of product However if product is returned due to factory defect within the first year CITC will cover the cost of returning the repaired unit to the customer 6 Limited warranty services do not cause an extension of the limited warranty per...

Reviews: