Chapter 5 Trial Run and Tuning Procedure
Revision June 2010
5-5
Stop (EMGS)”. (The setting value of parameter P2-10 to P2-17 and P2-36 is not set
to 21.)
If it is necessary to use “Emergency Stop (EMGS)” as input signal, the users only
need to confirm that which of digital inputs DI1~DI9 is set to “Emergency Stop
(EMGS)” and check if the digital input signal is ON (It should be activated).
4)
When display shows:
Reverse limit switch error:
Please check if any of digital inputs DI1~DI9 signal is set to “Reverse inhibit limit (NL)”
and check if the signal is ON or not.
Corrective Actions:
If it does not need to use “Reverse inhibit limit (NL)” as input signal, the users only
need to confirm that if all of the digital inputs DI1~DI9 are not set to “Reverse
inhibit limit (NL)”. (The setting value of parameter P2-10 to P2-17 and P2-36 is not
set to 22.)
If it is necessary to use “Reverse inhibit limit (NL)” as input signal, the users only
need to confirm that which of digital inputs DI1~DI9 is set to “Reverse inhibit limit
(NL)” and check if the digital input signal is ON (It should be activated).
5)
When display shows:
Forward limit switch error:
Please check if any of digital inputs DI1~DI9 signal is set to “Forward inhibit limit (PL)”
and check if the signal is ON or not.
Corrective Actions:
If it is no need to use “Forward inhibit limit (PL)” as input signal, the users only
need to confirm that if all of the digital inputs DI1~DI9 are not set to “Forward
inhibit limit (PL)”. (The setting value of parameter P2-10 to P2-17 and P2-36 is not
set to 23.)
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...