Chapter 8 MODBUS Communications
Revision June 2010
8-11
RTU Mode:
Command message:
Response message:
ADR 01H
ADR 01H
CMD 03H
CMD 03H
02H (Upper bytes)
Starting data
address
00H (Lower bytes)
Number of data
(Count by byte)
04H
00H
00H (Upper bytes)
Number of data
(Count by word)
02H
Contents of
starting data
address 0200H
B1H (Lower bytes)
CRC Check Low
C5H (Lower bytes)
1FH (Upper bytes)
CRC Check High
B3H (Upper bytes)
Contents of
second data
address 0201H
40H (Lower bytes)
CRC Check Low
A3H (Lower bytes)
CRC Check High
D4H (Upper bytes)
Command code: 06H, write 1 word
For example, writing 100 (0064H) to starting data address 0200H of ASDA-B2 series with
address 01H.
ASCII Mode:
Command message:
Response message:
STX ‘:’
STX ‘:’
‘0’
‘0’
ADR
‘1’
ADR
‘1’
‘0’
‘0’
CMD
‘6’
CMD
‘6’
‘0’
‘0’
‘2’
‘2'
‘0’
‘0’
Starting data
address
‘0’
Starting data
address
‘0’
‘0’
‘0’
‘0’
‘0’
‘6’
‘6’
Content of data
‘4’
Content of data
‘4’
‘9’
‘9’
LRC Check
‘3’
LRC Check
‘3’
End 1
(0DH)(CR)
End 1
(0DH)(CR)
End 0
(0AH)(LF)
End 0
(0AH)(LF)
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...