Chapter 6 Control Modes of Operation
6-18
Revision June 2010
6.3.6 Speed Loop Gain Adjustment
The function and structure of
speed control mode
is shown as the figure below:
There are two turning modes of gain adjustment: Manual and Auto modes. The gain of
ASDA-B2 series servo drives can be adjusted by using any one of three tuning modes.
Manual Mode:
User-defined loop gain adjustment. When using this mode, all auto
and auxiliary function will be disabled.
Auto Mode:
Continuous adjustment of loop gains according to measured inertia,
with ten levels of system bandwidth. The parameter set by user is default value.
The mode of gain adjustment can be selected by parameter P2-32:
P2 - 32
▲
AUT2 Tuning Mode Selection
Communication Addr.:
0240H, 0241H
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 5.6, Section 6.3.6
Unit: N/A
Range: 0 ~ 2
Data Size: 16-bit
Display Format: HEX
Settings:
0: Manual mode
1: AutoMode (PI) [Continuous adjustment]
2: Semi-Auto Mode [Non-continuous adjustment]
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...