Chapter 4 Display and Operation
4-8
Revision June 2010
4.4.2 JOG Operation
After entering parameter mode P4-05, the users can follow the following steps to perform
JOG operation. (Please also refer to Figure 4.4).
Step1.
Press the SET key to display the JOG speed. (The default value is 20 r/min).
Step2.
Press the UP or DOWN arrow keys to increase or decrease the desired JOG speed.
(This also can be undertaken by using the SHIFT key to move the cursor to the
desired unit column (the effected number will blink) then changed using the UP
and DOWN arrow keys. The example display in Figure 4.4 is adjusted as 100
r/min.)
Step3.
Press the SET key when the desired JOG speed is set. The Servo Drive will display
"JOG".
Step4.
Press the UP or DOWN arrow keys to jog the motor either CCW or CW. The motor
will only rotate while the arrow key is activated.
Step5.
To change JOG speed again, press the MODE key. The servo Drive will display "P4 -
05". Press the SET key and the JOG speed will displayed again. Refer back to #2
and #3 to change speed.
NOTE
1)
JOG operation is effective only when Servo On (when the servo drive is enabled).
Figure 4.4
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...