Chapter 6 Control Modes of Operation
Revision June 2010
6-19
Explanation of manual mode:
1.
When P2-32 is set to mode#0, the setting value of P2-00, P2-02, P2-04, P2-06,
P2-07, P2-25 and P2-26 can be user-defined. When switching mode #1 or #2 to
#0, the setting value of P2-00, P2-02, P2-04, P2-06, P2-07, P2-25 and P2-26 will
change to the value that measured in #1 auto-tuning mode or #2 semi-auto
tuning mode.
Explanation of auto-tuning mode:
The servo drive will continuously estimate the system inertia, save the measured
load inertia value automatically and memorized in P1-37 every 30 minutes by
referring to the frequency response settings of P2-31.
1.
When switching mode #1 or #2 to #0, the servo drive will continuously estimate
the system inertia, save the measured load inertia value automatically and
memorized in P1-37. Then, set the corresponding parameters according to this
measured load inertia value.
2.
When switching mode#0 or #1 to #2, enter the appropriate load inertia value in
P1-37.
3.
When switching mode#1 to #0, the setting value of P2-00, P2-04 and P2-06 will
change to the value that measured in #1 auto-tuning mode.
Explanation of semi-auto tuning mode:
1.
After the system inertia becomes stable (The display of P2-33 will show 1), it
will stop estimating the system inertia, save the measured load inertia value
automatically, and memorized in P1-37. However, when P2-32 is set to mode#1
or #2, the servo drive will continuously perform the adjustment for a period of
time.
2.
When the value of the system inertia becomes over high, the display of P2-33
will show 0 and the servo drive will start to adjust the load inertia value
continuously.
Manual Mode
When Tuning Mode Settings of P2-32 is set to 0, the users can define the proportional
speed loop gain (P2-04), speed integral gain (P2-06) feed forward gain (P2-07) and ratio of
load inertia to servo motor Inertia (1-37). Please refer to the following description:
Proportional gain: Adjust this gain can increase the position loop responsiveness.
Integral gain: Adjust this gain can enhance the low-frequency stiffness of speed
loop and eliminate the steady error. Also, reduce the value of phase margin. Over
high integral gain will result in the unstable servo system.
Feed forward gain: Adjust this gain can decrease the phase delay error
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...