Chapter 7 Servo Parameters
Revision June 2010
7-75
Data Size: 32-bit
Display Format: Hexadecimal
Settings:
This parameter is used to set the fourth most recent fault record.
P4 - 04
★
ASH5
Fault Record (N-4)
Address: 0408H, 0409H
Default: 0
Related Section:
Applicable Control Mode: ALL
Section 4.4.1
Unit: N/A
Range: N/A
Data Size: 32-bit
Display Format: Hexadecimal
Settings:
This parameter is used to set the fifth most recent fault record.
P4 - 05
JOG
JOG Operation
Address: 040AH, 040BH
Default: 20
Related Section: Section 4.4.2
Applicable Control Mode: ALL
Unit: r/min
Range: 0 ~ 5000
Data Size: 16-bit
Display Format: Decimal
Settings:
JOG operation command:
1. Operation Test
(1) Press the SET key to display the JOG speed. (The default value is 20 r/min).
(2) Press the UP or DOWN arrow keys to increase or decrease the desired JOG
speed. (This also can be undertaken by using the SHIFT key to move the
cursor to the desired unit column (the effected number will flash) then
changed using the UP and DOWN arrow keys).
(3) Press the SET when the desired JOG speed is displayed. The Servo Drive will
display "JOG".
(4) Press the UP or DOWN arrow keys to jog the motor either P(CCW) or N(CW)
direction. The motor will only rotation while the arrow key is activated.
(5) To change JOG speed again, press the MODE key. The servo Drive will
display "P4 - 05". Press the SET key and the JOG speed will displayed again.
Refer back to #(2) and #(3) to change speed.
(6) In JOG operation mode, if any fault occurs, the motor will stop running. The
maximum JOG speed is the rated speed of the servo motor.
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...