Chapter 7 Servo Parameters
7-30
Revision June 2010
P1 - 35
TDEC
Deceleration Time
Address: 0146H, 0147H
Default: 200
Related Section:
Applicable Control Mode: S
Section 6.3.3
Unit: msec
Range: 1 ~ 20000
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to determine the acceleration time to accelerate from 0 to
its rated motor speed. The functions of parameters P1-34, P1-35 and P1-36 are
each individual.
Please note:
1.
When the source of speed command is analog command, the maximum setting
value of P1-36 is set to 0, the acceleration and deceleration function will be
disabled.
P1 - 36
TSL
Accel /Decel S-curve
Address: 0148H, 0149H
Default: 0
Related Section:
Unit: msec
Section 6.3.3
Applicable Control Mode: S
Unit: msec
Range: 0 ~ 10000 (0: Disabled)
Data Size: 16-bit
Display Format: Decimal
Settings:
This parameter is used to make the motor run more smoothly when startup and
windup. Using this parameter can improve the motor running stability.
TACC: P1-34, Acceleration time
TDEC: P1-35, Deceleration time
TSL: P1-36, Accel /Decel S-curve
Total acceleration time = TACC + TSL
Total deceleration time = TDEC + TSL
Summary of Contents for ASD-B2-0121-B
Page 1: ......
Page 13: ...Table of Contents xii Revision June 2010 This page intentionally left blank...
Page 17: ...Chapter 1 Unpacking Check and Model Explanation 1 4 Revision June 2010 ECMA Series Servo Motor...
Page 87: ...Chapter 4 Display and Operation 4 12 Revision June 2010 This page intentionally left blank...
Page 131: ...Chapter 6 Control Modes of Operation 6 22 Revision June 2010 Time Domain...
Page 267: ...Chapter 8 MODBUS Communications 8 18 Revision June 2010 This page intentionally left blank...
Page 271: ...Chapter 9 Maintenance and Inspection 9 4 Revision June 2010 This page intentionally left blank...
Page 291: ...Chapter 11 Specifications 11 8 Revision June 2010 11 3 Servo Motor Speed Torque Curves...